Sector 10 AMP TYPE B 6kA MCB CIRCUIT BREAKER SVMCB10/B RED

£9.9£99Clearance
ZTS2023's avatar
Shared by
ZTS2023
Joined in 2023
82
63

About this deal

ELCBs (earth-leaking circuit breakers) use earthing as their primary method of controlling electrical current and preventing electrocution. They work by detecting any stray voltage on the enclosure of a device and then breaking the circuit if it exceeds a designated level. They perform a similar function to RCDs, but the latter detect stray voltage directly and so are now more favoured by electricians. What is the Difference Between MCBs and RCDs? An MCB is designed to protect against both overloading and short-circuiting. These are detected differently using separate processes. Overload protection is provided by the bimetallic strip using thermal operation, whereas short-circuit protection is provided by the tripping coil via electro-magnetic operation. Memera 2000 – There are several different styles of MCB's in this range but all will fit any Memera 2000 board. Memera 2000AD – These have a narrow terminal and only fit boards specifically marked Memera 2000AD. They won't fit in older boards.

Initially the range was made to BS3871 standards so Types 2 & 3 were available from 6A up to 63A in single and triple pole. RCBO's were also available but they were initially referred to as MCB/RCD units as the term RCBO was not really established as yet. Memshield 1 – These are a commercial breaker and come in various types (Type 2,3,B,C & D) depending upon the age. Most are M9 rated.

The Polestar range of breakers was unique because they had a higher than usual fault rating of 16kA where standard breakers at the time were 6kA and 9kA. What this meant was that Polestar could be used in areas where a high kA was required without having to use Moulded Case Breakers (MCCB's) or HRC fuse carriers. Crabtree Polestar breakers are also unique in that they are much wider (25mm) than a standard mcb (18mm). This extra width was needed for the bigger arc splitter to allow for a higher kA rating. Delta decided to keep the brands MEM and Bill separate until 1998 when they finally phased out the Bill brand. What most people don't realise is that all the products that were manufactured were identical in both brands. Delta manufactured the products and either labelled them MEM or Bill. Qwikline – This is the most common Square D breaker and the part numbers will always start QO. Available in types 2,3 & 4 with M6 or M9 breaking capacities for early BS3871 breakers or types B,C & D with 6kA or 10kA breaking capacities. These styles have the push-fit electrical connection and push-fit mechanical connection. These are available in single, double and triple pole.

Residual current devices ( RCDs) are a different form of electrical safety equipment. While MCBs have a general function, RCDs are specifically built to protect against the frequently fatal risk of electrocution from touching exposed wires or incorrectly earthed cables. They operate directly within electrical circuits to detect faults and cut off potentially hazardous currents. You can also buy MCB's pre-fitted with a pod in both the Memshield 2 and Memera 2000 ranges. These are usually just the 30mA size but field fit versions are availble is the following sizes: Bill Switchgear was probably one the oldest British electrical brands and was especially known for bigger switching devices like triple pole fuse switches and switch fuses and LV panelboards. The company was aquired by Delta in 1973 who also owned another well known brand, MEM.Fortunately the situation with Bill and MEM MCCB's is not as confusing. Firstly MCCB's are made to a different standard to MCB's, BS60947-2. Whilst that standard has been updated to allow for new technologies it still remains as the current British Standard. MEM first started manufacturing circuit breakers in 1965 and were one of the UK's biggest names in circuit protection. Now they go under the trade name of Eaton but still use the MEM name on some products. After 1994 the British Standard of BS60898 came into effect and the range was changed to Types B, C & D and now included double pole mcb's as well. RCBO's were now being widely used and theses were available in Types B & C although it's rare to see Type B in use as most installations were commercial.